Minggu, 25 September 2011

Engine modified for Racing

Engine modified for racing is in order to power up the engine.parts specification
and modified is: spark plug spec./ignition coil spec.in racing,generator coil
modified to reduction 3-5mm, piston modified to reduction 10-20mm for weight of
method to reduction,by workshop services. The piston is to change of size big more
and the part should be genuine state
The part of mixing fuel and air/carburator modified of hole of fuel to big more
hole of air to big more, but mixing is 32lb/2lb fuel state.If used Turbocharger is
to modified to fill the air the big more from spec,standart. This modified is
included engine 2(two),4(four) stroke,diesel and fuel gas or gasoline system

Sabtu, 24 September 2011

Ignition of Automobile

Ignition of automobile is spark in combustion of engine by gasoline fuel (C6H12O6)
The System is conventional, parts of the system is: Battery, arm/nocken as, cut
ignition, ignition coil, spark plug, and the operate system is, 12Vdc battery
combined with coil generator connecting to ignition coil to spark plug.Between
12Vdc battery and ignition coil to install cut ignition governor automatic,
setting by engineer/technician to operate that the system if compression step
before point up/8 degree ignition will connected. If before the setting ones
is wrong condition the system will be back step occur,so the engine cannot running
If the setting after the setting ones, it is wrong condition the engine can running
but the power of engine will be loose. So the setting should be match in order to
have the power of the engine is full power.
The system is operate to engine 2(two) stroke and 4(four) stroke by gasoline fuel
The system is conventional to ignition spark chamber of internal combustion engine

Kamis, 22 September 2011

Fire Alarm Gong For Building

Fire alarm gong for building is very important to indicate that the sprinkler
system on the Building is have problem in sprinkler on the building is problem
occur like is head sprinkler crack, broke,or brake against flame cause fire
occur on the building in location fire occur. cause the head sprinkler broke
the pressure in installation of sprinkler system to be go down. So will water
flow occur indicate flow switch and than have flow on the motor alarm gong,
water flow press the impeller motor alarm and than alarm gong ring on and than
Fire pump,Jokey, electric, diesel pump will run on if rich fire matter
Of this matter is indicate that the building have problem about Fire safety
the building. So the technician or security on the building check location
as soon as possible.Beside this system any safety first exactly is the Fire
alarm fire is first indicate that the condition fire occur,the fire alarm first
will ring by bell because have signal in from the detectors,heat or smoke send
the signal to Fire panel alarm and system fire alarm will life ring on hazard

Selasa, 20 September 2011

Fire Pre-Action System

Fire Pre-Action system is to void the fire occur by dry system of the location
as protected like is Data center, Server Room, IT-Room,or of manufacture of
factory need protection but dry in condition like: Electronic manufacture,electric
manufacture, chemical industry,library,or etc as can not get wet condition
Installation and operation is need of parts as follow:Gate valve, Chamber of
deluge,trim set deluge, trim set solenoid valve, solenoid valve, Flow switch
Pressure switch,templer switch, compressor unit,Sprinkler head bulb type,safety
valve,control panel, detectors, and parts of related.The operation is after the
all of parts is installed if the fire occur, detector will detected and send signal
so control panel send output signal to solenoid Pre-Action open the deluge clapper
the water discharge through clapper to system. But the water still stand by in
pipe system mix with air the pressure is 150 -175 psi. So if the fire flame to
bulb of sprinkler head break and water discharge to location.
The standby condition deluge clapper is close and the pipe system fill the air need
air pressure 120psi without leak but if the pressure is go down the air compressor
will automatic run to acheive the pressure mentioned by pressure reference...

Sabtu, 17 September 2011

Deluge Valve Chamber

Deluge valve chamber is to protection the location from the fire
occur. The part of is: Gate valve OS&Y,NFPA, Chamber,Trim set
Flow switch, pressure switch, solenoid valve, alarm gong
Smoke, Heat Detectors, panel control.The system operate is
electric system need current 24Vdc to operate the fire alarm system
the signal from the detectors cause smoke or heat will send
signal to control panel and panel will send out signal suppression
to solenoid 24 Vdc so the chamber will open and water have pressure
9-10 kg/cm2, 135-150 psi will trough out to system so the water will
discharge by sprinkler head pendent or upright on the area
protection eg:Transformator, workshop area, special area should be
protection need high pressure and high flow rate but safe for
water or wet condition. The type of sprinkler head is open type
so if occur the fire the water will discharge by spray nozzle/head
sprinkler to follow specification the NFPA-20

Kamis, 15 September 2011

Fire Hydrant System

Fire Hydrant system is used of the buildings, offices, hospitals,
apartments,power plant or etc...the parts of fire hydrant ie: pumps
panels control, pipe SCH-40,fire hose, nozzle, and valves
the size of pump depending the building size, the size pump is
250 USGPM up, split case or centrifugal end suction
The pump will suction the water from ground tank and will
discharge to system the building with pipe installation connection
by welded or tread size and to be installed to the building
Beside the pump size also used Jokey pump is to get stability of
the pressure will start and stop by automatic system depend
pressure what you want.The building big size is used complete set
ie:Diesel fire pump, Electric main pump, Jokey pump
and the size of those pump is depending the building size

Rabu, 14 September 2011

Fire Sprinkler System for Building

Parts of Fire sprinkler system: Head sprinkler of type is pendent, conventional,
upright,mirage concealed,spray, grade temperatur is 68,96,141,282 celcius
degree
Installation system is:pipe SCH-40,SCH-80,Medium size,galvanized,black steel
pipe size is depending pressure and flow rate the water
Coverage area is light hazard,for example,church,clubs,hospitals,museum
offices (10 gpm per225sq.ft)
Ordinary hazard:Restaurants, Bakeries,show room,Laundries,Library
(15 gpm per 130sq.ft)
Extra hazard: Plastic processing, Solvent cleaning, Varnish, Saw Mills
(40 gpm per 100sq.ft)standart to follow NFPA-13 is ad...

Jumat, 09 September 2011

Fire Alarm For Building

The fire alarm system for building is very important since is to prevent
of fire occur. The building must be to install the system fire alarm
The parts of fire alarm is: Master control panel, terminal box, MDF
cables 1,5mm2 square, terminals, smoke detector, rate-of-rise
detector, Fixed temperatur detector, gas detector, manual call point
alarm bell, indicating lamp, remote indicating lamp (for hotel & apartment)
The system operate is if blame, fire occur will heating or smoke in location
area and will catch of smoke detector or heat detector so the detector
will operate contact send signal to MCFA as input signal and than MCFA
will out signal send to alarm bell and indicating lamp will be life
The all operate is used usually 24Vdc by nicad battery and input Power
generation

Kamis, 08 September 2011

Anti Thief Automobile

Anti thief automobile is designed by own. If we have automobile or car, motorcycle
I have idea to prevent of thief so we property is not loose. This is technical installation
method as described you firstly please prepare is 400 inci or 10 meters cable 2x1mm2
stop contact 1pc. seek the cable installation go to coil ignition cut and connect paralel
method to stop contact operate to SC if is not want to life please move to stop position
this is cable have voltage 12Vdc or 24Vdc before coil ignition and after coil ignition
is 20.000 - 30.000Vdc of spark plug automobile so we can safe of we have property
also can be able combined with security alarm or horn will be added stop contact 1pc
again and install connected is paralel with stop contact first ones

Rabu, 07 September 2011

Engine Two Stroke better

Engine two stroke is engine has steps as follows: step 1,is suction and discharge
exhaust, step2 is compression and power out. so 1,one rotation 1,one power step
usually used in heavy industry, power plant, racing or motor cycle and portable
engine and can be operation of diesel engine to heavy industry and gas/fuel engine
to racing, motorcycle and portable engine. Combustion type is mixing fuel and oil
lubricant fill to combustion chamber and will combustion occur beside this matter
lubricant also used to lubrication engine running. The engine as simple designed
no valves intake and exhaust in the combustion parts so the engine is simple
assembled also the  engine is simple volume. Engine two stroke no concerned
about over heating because has double lubrication (combustion and engine
rotation running usually described in specification as follows:

Senin, 05 September 2011

Engine Turbocharger

Turbocharger is to fill air pressure with over than 1kg/cm2 or 15 psi to chamber
of the engine.Usually to install in automobile, motor racing or heavy duty of
engine is use to rise of acceleration, power. Type of turbocharger is centrifugal
and rotary or piston compressor to install near by the engine system
Centrifugal system is to install in exhaust chamber the engine, impeller will be
running by the pressure gas exhaust in also to pressure air more than 15 psi
to fill the chamber so the engine is power up (split case impeller system)
Rotary or piston compressor is with machine compressor system suction
and discharge air to fill the chamber more than 15 psi so the engine will
high in performance is difference against engine system conventional as follow..

Jumat, 02 September 2011

Brake economical use

Type of brake automotive, motorcycle, heavy duty automobile is disk and
drum type and used we suggest is genuine product to friction is very good
Specification of those automobile should be able to follow the  manufacture
standard products e.g: no in overloads, standard speed, genuine parts for
layer shoes brake also. For this attention should be install and maintenance
by technician by experience.
Operation brake is by manual operate the system is by string cable, pneumatic
system, hydraulic system. The brake system included: clutch of engine
wheel brake, rotation brake engine and can be operate by manual or automatic
system have had designed by engineer manufacture products

Use Tire Economical

Tire of automobile or motorcycle is very important used
type of rubber tire Synthetic black rubber (SBR) can absorb
the oil so no silk if had the oil layer usually used racing or industrial
Natural black rubber (NBR) for plan used. Pressure fill the air or
nitrogen is 30psi or 2,2 kgcm2 and load no more from the specification
no often to operate brake and low acceleration and speed is
economical rotary per minute so road condition is standart to
temperatur and broken maintenance and keep clean also
For standart used of tire is 2 years depending motive of the tire
products manufacture in the following specification

Kamis, 01 September 2011

Economical Fuel consumption of Vehicle

Vehicle is very important needs to moving for everyone in this life
we can use the car, motorcycle is want to operation is good and
inconvenience in order to no trouble in our activity. Beside in good
operation we need also consumption the fuel is economic
Something  can support to the economical the fuel is: 1, should be
loose of friction  2, the pressure wheel rubber is 30 psi 3, adjustment
the brake is accurate 4, Rotation per minute the engine no suddendly
is up and down 5, Running the engine is economic rotation 2500rpm
so the filters, oil, air should be clean. Hoping the mixing achieve  2 pons
fuel by 32pons air so the consumption fuel will be economical...

Selasa, 30 Agustus 2011

The Fire Protections

Fire protection is to prevent of fire occur covering in around our stayed like
houses, apartments, hospitals,  buildings, plan, or related with flame of fire
occur the type of fire protection is: the Fire alarm, fire hydrant, fire sprinkler
fire wall aerosol, FM-200, CO2, hallotron ar etc...
The fire alarm is used for preventive occur the fire first is installation system
by electronic system 24Vdc. The part of fire alarm: smoke detector, heat
detector, fix and rate of rate, gas detector, beam detector, panel control,
terminal box, MDF, manual call point, lamp 24Vdc, bell 24 Vdc or etc...
The fire hydrant system is secondary action to handled the flame of fire
the action is used of water will discharge pass the nozzle the water will
discharge had pressure 150-300 psi by water pump and installation by pipe
SCH-40 or medium, size the parts is water pump, flexible connection, check
valve, gate valve, fire hose or etc...

Senin, 29 Agustus 2011

Air Compressor Machine

The Air Compressor is machine coupled the electrical motor or mechanical
engine with screw or piston machine
Type of the air compressor is: oil free type, piston type, screw type rotary
Air compressor machine running if the primary machine on so operate the
screw of piston to suction and discharge the air fill to vessel up to the
pressure as mentioned like 45 psi up to 450 psi to follow the system
coallising filtering the dust
Oil free is piston type the compressor running suction and discharge air
by the piston cycle
Part of the compressor system is: engine mechanical or motor electric
,screw rotary or piston, air filter, oil filter, oil sparator, coalising filter
and vessel to air storage with air pressure such as mentioned eg.

Minggu, 28 Agustus 2011

Generator Sets (Genset)

Type of generator set is: open type, silent type, troly type, portable type
The generator set is couple engine with generator electric and automatic
voltage regulator
Type of engine is: conventional system, electric system
Type of cooler: inter cooler, radiator cooler
Inter cooler: the air intake will suction to combustion camber, tube
cooler passed so air intake to be go down temperature is good
to combustion process and power the engine will be going up
Turbocharger type: centrifugal rotary and compressor system
The genset running will out the electrical voltage 110Vac, 220 Vac
380 Vac have setting by Automatic Voltage Regulator (AVR)

Minggu, 21 Agustus 2011

Pumps Machine

Pump is used to move the fluid like the water, oil, fuel,chemicals or etc
The type of pumps is centrifugal pumps, piston pump, screw pump
the centrifugal pump is rotary pump, the stator is impeller house,
the rotor is impeller rotary, suction and discharge will be occur
this running the pump, fluid in use usually chemical, water
Piston pump the piston use for suction and discharge the fluid
the fluid is oil and fuel
Screw pump is rotary pump but the impeller is long size the house
of impeller like vessel fluid in use is water and chemical
the capacity of the pumps USGPM the pressure of pumps
is total head difference pressure  suction and discharge

Sabtu, 20 Agustus 2011

The Fire Protections

The fire protection is fire extinguisher system included: ABC dry chemical, CO2, FM-200, Fire Alarm system, Fire Hydrant system, Fire Sprinkler system is used for to void of fire occur in our stay live residential, factory
hotels, apartment or etc
we suggest if you are stay in around should be install the fire system
also in your kitchen should be to install gas detector to detection
if leak the gas cooker occurs
Fire sprinkler system installed the building at lease 5th floor
to follow the government attention as described

Kamis, 18 Agustus 2011

The Filters

Type of filters is: steel screen, paper,mesh,or etc
media of fluid is water, oil,gas, chemicals
Hydraulic filters, fuel filter, oil filter, air filter
filter for engine heavy duty
filters is made very accurate from manufacture
Filter used for to void damage of the equipments

Selasa, 16 Agustus 2011

Steel of Compositions

The description of the metallurgy is stainless steel, steel, autectoid steel
the metal will be to build of industrial, construction, factory, automotive industry
or etc, to acheived 0,8 composition of autectoid steel should be handle
with hardening process to follow heating and to fill the water have mixed with salt
the ingredient of salt as follow...
the composition of steel as follow: under 0,8 C composition is steel hypoautectoid
is 0,8 C composition is steel autectoid,
0,8C above is steel hyperautectoid such as described in the following item..